3P/1P Rack-Mount Online UPS 10KVA to 20KVA

This rack-mount 3P/1P online UPS 10–20kVA provides reliable double-conversion power protection for servers, network equipment, telecom systems, industrial control devices, medical IT systems, financial equipment, and other critical single-phase loads. With 3-phase input and single-phase output, pure sine wave output, input power factor ≥0.99, output voltage regulation ±1%, and high AC mode efficiency up to 94%, it helps protect sensitive equipment from outages, voltage fluctuations, frequency instability, and power quality problems.

Designed as a long-run external battery model, this UPS supports 192VDC or 240VDC battery configuration, 4A standard charging current, optional 10A charging current, RS232 and Ethernet communication, and optional USB or MODBUS extension cards. Its rack-mounted design, LCD/LED status display, and compact 3U/4U chassis make it suitable for server rooms, network cabinets, telecom rooms, industrial control rooms, and other critical power applications requiring extended backup time.

Features

Double-Conversion Online Technology

Double-conversion online topology provides continuous power conditioning and stable output power for sensitive and critical equipment.

3-Phase Input / Single-Phase Output

The UPS uses 3-phase input and single-phase output, making it suitable for facilities with 3-phase utility power and critical single-phase equipment.

10–20kVA Capacity Range

Available in 10kVA, 15kVA, and 20kVA models, with output power ratings of 9kW, 13.5kW, and 18kW.

Pure Sine Wave Output

Pure sine wave output provides stable and clean power for servers, network equipment, telecom systems, industrial controllers, and sensitive electronics.

High Input Power Factor

Input power factor ≥0.99 helps improve electrical efficiency and reduce the impact on upstream power systems.

Wide Input Voltage Range

Wide input voltage range supports stable operation in areas with fluctuating or unstable mains power.

Precise Output Voltage Regulation

Output voltage regulation of ±1% helps deliver stable power to connected critical loads.

High Efficiency Operation

AC mode efficiency reaches up to 94%, helping reduce energy loss and long-term operating costs.

External Battery Long-Run Design

The UPS is designed for external battery connection, allowing backup time to be configured according to project requirements.

192VDC / 240VDC Battery Configuration

Supports 192VDC or 240VDC battery systems, corresponding to 16 or 20 batteries depending on configuration.

Standard and Optional Charging Current

The long-run model supports 4A standard charging current, with 10A optional charging current available for faster charging or larger battery systems.

Strong Overload Capability

The UPS supports defined overload operation in both AC mode and battery mode, helping protect the system during temporary load impact.

Rack-Mounted Chassis

The rack-mounted design is suitable for server racks, network cabinets, telecom rooms, and space-limited equipment rooms.

LCD and LED Display

LED display provides mains status, battery status, load level, battery level, and operation mode. LCD display shows input mains voltage, frequency, load level, operation mode, and health status.

RS232 and Ethernet Communication

Standard RS232 port and Ethernet card support local and network-based UPS monitoring.

Optional Extension Cards

Optional USB card and MODBUS card are available for extended communication, monitoring, and system integration.

Quiet Operation

Noise level below 55dB at 1 meter makes the UPS suitable for server rooms, network rooms, and technical equipment areas.

Specifications

MODEL3C-10KRL3C-15KRL3C-20KRL
CAPACITY10KVA/9KW15KVA/13.5KW20KVA/18KW
TOPOLOGYDouble Conversion Online UPS
PHASE3-phase in / 1-phase out
INPUT
Input Wiring3 Phases (L1,L2,L3,N)/N+PE
Nominal Voltage208/220/230/240VAC
Input Voltage RangeLine-Neutral: 90~300VAC, Line-Line: 150~500VAC
Frequency Range40Hz-70Hz
Input Power Factor≥0.99
OUTPUT
Output WiringL/N+PE
Output Voltage208/220/230/240VAC
Voltage Regulation±1%
Output Frequency50/60 ± 4Hz (Sync Mode) / 50/60 Hz ± 0.1% (Free Run)
Output WaveformPure Sine Wave
Output Distortion (THDV%)<2%(Linear Load), <7%(None-Linear Load)
Over Load
Capability
AC Mode10Min@105%~125%, 30Sec.@125%~150%, 0.5Sec.@>150%
Battery Mode10Sec.@101%~110%, 0.5Sec.@>110%
EFFICIENCY
AC Mode94%
Battery Mode192VDC: 92% / 240VDC: 93%
BATTERY & CHARGE
Battery Voltage192/240VDC 16/20 pcs
Battery CapacityExternal
Charging CurrentLong-run Model: 4A; 10A (Optional)
PHYSICAL
Chassis StyleRack-Mounted
Rack  Dimension10KVA: 438mm(W) x 132mm(3U)(H) x 530mm(D)
15KVA/20KVA: 438mm(W) x 176mm(4U)(H) x 530mm(D)
Weight (kg)18.525.626.1
HMI
LED DisplayMains / Battery Status, Load Level, Battery Level, Operation Mode
LCD DisplayInput Mains Voltage, Frequency, Load level, Operation Mode, Health Status
Standards CommunicationRS232 port, Ethernet Card
Optional Extension CardUSB Card, MODBUS Card
ENVIRONMENT
Temperature range-0~40℃
Relative Humidity0-98% (Non-condensing)
Noise Level<55dB @ 1 meters
* Product specifications are subject to change without further notice.

Applications

Server Rooms

Provides reliable backup power for servers, storage systems, switches, firewalls, and small-to-medium IT infrastructure.

Network Cabinets

Suitable for routers, switches, communication devices, and network equipment installed in standard rack environments.

Telecom Rooms

Supports telecom systems, communication devices, transmission equipment, and network infrastructure requiring stable single-phase output power.

Industrial Control Systems

Helps protect PLC systems, industrial PCs, monitoring devices, control room equipment, and automation-related electronics.

Medical IT Systems

Suitable for healthcare IT rooms, medical workstations, diagnostic support systems, and selected sensitive medical electronics.

Financial and Banking Systems

Provides backup power for bank IT rooms, payment systems, branch infrastructure, transaction systems, and financial service equipment.

Security and Surveillance Systems

Supports CCTV systems, NVRs, access control systems, alarm systems, and security network equipment.

Commercial IT Infrastructure

Protects office servers, VoIP systems, network systems, business applications, and other critical office electronics.

Edge IT and Remote Sites

Suitable for edge IT cabinets, remote communication sites, branch offices, and unstable power areas requiring extended backup time.

Frequently Asked Questions

What is this rack-mount 3P/1P online UPS used for?

This UPS is designed to provide reliable backup power and power protection for servers, network equipment, telecom systems, industrial control devices, medical IT systems, financial systems, and other critical single-phase loads.

What does 3P/1P mean?

3P/1P means 3-phase input and single-phase output. It is suitable for sites with 3-phase mains power where the protected equipment requires single-phase output power.

What capacity range is available?

This UPS is available in 10kVA, 15kVA, and 20kVA models, with output power ratings of 9kW, 13.5kW, and 18kW.

Is this a long-run UPS model?

Yes. This is a long-run external battery model. It is designed to connect with external batteries so backup time can be configured according to load and runtime requirements.

What battery voltage does this UPS support?

It supports 192VDC or 240VDC battery configurations, usually corresponding to 16 or 20 batteries depending on the system design.

What is the charging current?

The standard charging current is 4A, with 10A optional charging current available for larger external battery systems or faster recharge requirements.

Does this UPS provide pure sine wave output?

Yes. It provides pure sine wave output, making it suitable for servers, network devices, telecom equipment, industrial control systems, and sensitive electronics.

What communication options are available?

The UPS includes RS232 and Ethernet communication. Optional USB and MODBUS extension cards are available for monitoring and system integration.

Is this UPS suitable for standard server racks?

Yes. It uses a rack-mounted design. The 10kVA model is typically 3U, while the 15kVA and 20kVA models are typically 4U.

Is this UPS suitable for data centers?

It is suitable for small server rooms, network rooms, edge IT infrastructure, telecom rooms, and critical single-phase loads. For medium or large data centers, a three-phase output UPS or modular UPS may be more suitable.

What information is needed to choose the right model?

To recommend the right model, the following information is usually required: load capacity, input/output voltage, required backup time, battery configuration, rack space, communication requirements, installation environment, and whether optional MODBUS, USB, or Ethernet monitoring is needed.