Features
Online Double-Conversion Technology
Online double-conversion topology provides continuous power conditioning and stable output power for sensitive and critical equipment.
Single Phase Input and Output
Single phase input and single phase output design makes this UPS suitable for offices, server rooms, telecom rooms, industrial control systems, and commercial power protection applications.
Wide Capacity Range
Available from 1kVA to 30kVA, this UPS covers small IT loads, medium power systems, and higher-capacity single-phase critical applications.
Pure Sine Wave Output
Pure sine wave output provides clean and stable power for servers, network equipment, medical IT systems, communication devices, and sensitive electronics.
Zero Transfer Time
With online double-conversion operation, the UPS provides 0ms transfer time, helping prevent interruption to connected critical loads during mains power disturbances.
Wide Input Voltage Range
The wide acceptable input voltage range helps the UPS operate reliably in unstable mains power environments and reduces unnecessary battery discharge.
Stable Output Voltage
Output voltage stability helps maintain reliable operation for connected equipment and reduces the risk of abnormal shutdown or equipment malfunction.
Output Power Factor 0.8
Output power factor 0.8 provides practical active power capacity for IT, telecom, industrial, and commercial power protection applications.
ECO Mode for Energy Saving
ECO mode helps improve operating efficiency and reduce energy consumption when input power conditions are stable and suitable.
Emergency Power Off Function
The EPO function allows the UPS system to be shut down quickly in emergency situations when connected to the proper external control mechanism.
Strong Overload Capability
The UPS supports defined overload operation, helping protect the system during temporary overload conditions and load impact events.
Short-Circuit Protection
Built-in short-circuit protection helps improve system safety and protect both the UPS and connected equipment.
Over-Temperature Protection
Over-temperature protection helps protect the UPS from abnormal thermal conditions and supports safer long-term operation.
External Battery Long-Run Design
The UPS supports external battery configuration, allowing backup time to be designed according to load capacity and project requirements.
Selectable Charging Current
Charging current can be selected according to battery capacity and backup time requirements, supporting more flexible battery system configuration.
MODBUS RS-232 / RS485 Communication
MODBUS RS-232/RS485 communication supports system monitoring, local communication, and integration with power management or industrial monitoring platforms.
Optional SNMP Monitoring
Optional SNMP enables network-based UPS monitoring and power management through SNMP manager or web browser.
IP21 Protection
IP21 protection helps provide basic protection for indoor installation environments.
Low Noise Operation
Noise level below 58dB at 1 meter makes the UPS suitable for equipment rooms, server rooms, and technical areas.
Specifications
| MODEL | C1KL | C2KL | C3KL | C6KL | C10KL | C15KL | C20KL | C30KL | |
| PHASE | 1 phase in / 1 phase out | ||||||||
| CAPACITY* | 1000VA/800W | 2000VA/1600W | 3000VA/1800W | 6000VA/4800W | 10KVA/8KW | 15KVA/12KW | 20KVA/16KW | 30KVA/24KW | |
| INPUT | |||||||||
| Nominal Voltage | 208VAC/220VAC/230VAC | ||||||||
| Acceptable Voltage Range | 165-275 VAC @ 16 pcs of batteries / 185-275VAC @ 18 pcs of batteries | ||||||||
| Frequency | 40Hz ~ 55Hz or 57Hz ~ 63Hz | ||||||||
| OUTPUT | |||||||||
| Nominal Voltage | 208VAC/220VAC/230VAC | ||||||||
| Connection Type | Hardwire 3-wire (1Ph+N+G) | ||||||||
| Waveform | Pure Sinewave | ||||||||
| Output Voltage Stability | Steady State | ±1% | |||||||
| Transient State | ±5% | ||||||||
| Frequency | 50 Hz | ||||||||
| Frequency Stability | ±1% | ||||||||
| Frequency Synchronisation Range | ± 5Hz (Equal to bypass working range) | ||||||||
| Frequency Synchronisation Speed | 1~2Hz/s | ||||||||
| Power Factor | 0.8 | ||||||||
| Crest Factor | 3:1(max.) | ||||||||
| Total Harmonic Distortion (THDv) | ≦3%THD (Linear Load); ≦5%THD (Non-linear Load) | ||||||||
| Dynamic Recovery Time (III Grade) | 0%~100% RCD load : <100 ms recover to 90% of nominal voltage | ||||||||
| Transfer Time | 0 ms | ||||||||
| Overload Capability | 110% ~ 120% for 30 min; 120% ~ 130% for 5 min; >130% for 10 sec | ||||||||
| Short-circuit Capability | 60~100 ms | ||||||||
| Transient Response Time | < 5 ms | ||||||||
| BYPASS | |||||||||
| Connection Type | Hardwire 3-wire (1Ph+N+G) | ||||||||
| Input Voltage Range | 220VAC ± 25% | ||||||||
| Overload Capability | 1.5 In ~ 1.8 In 1h~30s | ||||||||
| Short-circuit Capability | 1.8 In ~ > 2.0 In 30s~200ms | ||||||||
| SYSTEM | |||||||||
| Efficiency | Line Mode | 87% | |||||||
| Battery Mode | 91% | ||||||||
| ECO Mode | 95% | ||||||||
| EPO Function | Yes | ||||||||
| Over Temperature Protection | Yes | ||||||||
| Standard | IEC 62040-2 EMC/EMI, IEC62040-1 Safety | ||||||||
| BATTERY & CHARGER | |||||||||
| Charger | Charger Voltage | 290VDC (16pcs) / 246VDC (18pcs) | |||||||
| Charging Current(max) | 2A/4A/8A (selectable) | ||||||||
| Battery | Battery Numbers | 8/16/18 pcs | |||||||
| Battery Voltage | 96/192VDC | ||||||||
| PHYSICAL | |||||||||
| IP Protection | IP21 | ||||||||
| Dimension,DxWxH(mm) | 590 x 215 x 470 | 590 x 215 x 470 | 590 x 215 x 470 | 600 x 230 x 585 | 600 x 230 x 585 | 715 x 335 x 710 | 760 x 420 x 960 | 760 x 420 x 960 | |
| Net Weight(kgs) | 38.5 | 38.5 | 44.5 | 59 | 73.5 | 103.5 | 164 | 180 | |
| ENVIRONMENT | |||||||||
| Operating Temperature | 0~40°C | ||||||||
| Humidity | 0~90% (non-condensing) | ||||||||
| Noise Level | Less than 58dB @1 Meter | ||||||||
| MANAGEMENT | |||||||||
| Modbus RS-232/RS485 | Supports Windows® 2000/2003/XP/Vista/2008/7/8/10, Linux and MAC | ||||||||
| Optional SNMP | Power management from SNMP manager and web browser | ||||||||
| *Product specifications are subject to change without further notice. | |||||||||
Applications
Server Rooms
Provides stable backup power for servers, storage systems, switches, firewalls, and small-to-medium IT infrastructure.
Network and Communication Rooms
Suitable for routers, switches, telecom devices, communication systems, and network infrastructure requiring stable single-phase power.
Telecom Systems
Supports telecom equipment, transmission systems, edge communication sites, and network devices requiring long-run backup power.
Industrial Control Systems
Helps protect PLC systems, industrial PCs, monitoring equipment, control room devices, and automation-related electronics.
Medical IT Equipment
Suitable for healthcare IT rooms, medical workstations, diagnostic support systems, and selected sensitive medical electronics.
Financial and Banking Systems
Provides backup power for bank IT rooms, payment systems, transaction equipment, branch infrastructure, and financial service systems.
Security and Surveillance Systems
Supports CCTV systems, NVRs, access control systems, alarm systems, and security network equipment.
Commercial Office IT Infrastructure
Protects office servers, VoIP systems, network cabinets, business systems, and other critical office electronics.
Education and Laboratory Equipment
Suitable for computer labs, campus IT rooms, research workstations, laboratory systems, and network infrastructure.
Long Backup Time Applications
External battery support makes it suitable for sites that require longer backup time, such as unstable power areas, remote offices, telecom rooms, and critical business systems.
Frequently Asked Questions
What is this single phase online UPS used for?
This UPS is designed to provide backup power and power protection for servers, network equipment, telecom systems, medical IT equipment, industrial control devices, financial systems, security systems, and other critical single-phase loads.
What capacity range is available?
This UPS is available from 1kVA to 30kVA, covering small IT equipment, office systems, network rooms, server rooms, and higher-capacity single-phase applications.
Is this a long-run UPS model?
Yes. This UPS supports external battery configuration, making it suitable for applications that require longer backup time than standard internal battery models.
Does this UPS provide pure sine wave output?
Yes. It provides pure sine wave output, which is suitable for servers, network equipment, telecom devices, industrial controllers, medical IT systems, and sensitive electronics.
Does this UPS have zero transfer time?
Yes. As an online double-conversion UPS, it provides 0ms transfer time, helping protect critical loads from interruption during mains power disturbances.
What battery configuration does this UPS support?
The UPS supports flexible external battery configurations, including different battery numbers and DC voltage options depending on model and project requirements.
Can the charging current be adjusted?
Yes. Charging current is selectable, allowing the UPS to better match different external battery capacities and backup time requirements.
Does this UPS support ECO mode?
Yes. ECO mode helps improve operating efficiency and reduce energy consumption when mains power quality is stable.
Does this UPS support EPO?
Yes. Emergency Power Off function is supported, allowing fast shutdown in emergency situations when properly connected.
What communication options are available?
The UPS supports MODBUS RS-232/RS485 communication, and optional SNMP is available for remote monitoring and network-based power management.
Is this UPS suitable for data centers?
It is suitable for small server rooms, network rooms, edge IT infrastructure, telecom rooms, and critical single-phase loads. For medium or large data centers, a three-phase output or modular UPS may be more suitable.
What information is needed to choose the right model?
To recommend the right model, the following information is usually required: load capacity, input/output voltage, required backup time, battery configuration, installation environment, communication requirements, SNMP monitoring needs, and whether ECO mode or EPO integration is required.