Configuration Options
1P/1P Configuration
The single-phase input / single-phase output configuration can be used in sites where both the mains power supply and the protected equipment are single-phase. This provides more flexibility for projects with different site power conditions.
3P/1P Configuration
The 3-phase input / single-phase output configuration is suitable for facilities with 3-phase mains power where the protected equipment requires stable single-phase output power. This is commonly used in server rooms, telecom rooms, industrial control rooms, commercial facilities, and technical equipment rooms.
Features
True Online Double-Conversion
True online double-conversion technology provides continuous power conditioning and stable output power for critical equipment.
3P/1P and 1P/1P Operation Support
The UPS supports both 3-phase input / single-phase output and single-phase input / single-phase output operation, offering flexible installation for different power environments.
DSP Control Technology
DSP control improves UPS performance, response accuracy, and system reliability for demanding power protection applications.
Output Power Factor 0.8
Output power factor 0.8 provides practical active power capacity for servers, telecom equipment, industrial control systems, and commercial critical loads.
Active Power Factor Correction
Active power factor correction in all phases helps improve input power quality and reduce impact on upstream electrical systems.
Pure Sine Wave Output
Pure sine wave output provides clean and stable power for sensitive electronic equipment, servers, network devices, and communication systems.
Zero Transfer Time
Online double-conversion operation provides zero transfer time during mains power interruptions, helping maintain continuous output power.
Wide Input Voltage Range
The wide input voltage range helps the UPS operate reliably in unstable mains power environments and reduces unnecessary battery discharge.
50Hz/60Hz Frequency Converter Mode
Frequency converter mode allows the UPS to provide fixed 50Hz or 60Hz output for equipment requiring specific frequency conditions.
ECO Mode for Energy Saving
ECO mode improves operating efficiency and helps reduce energy consumption when input power quality is stable.
Programmable Power Management Outlets
Programmable outlets allow selected loads to be managed according to backup priority, helping extend runtime for critical equipment.
Emergency Power Off Function
The EPO function allows fast UPS shutdown in emergency situations when connected to the proper external control mechanism.
Generator Compatible
Generator compatibility allows the UPS to work with generator input while continuing to deliver stable output power to connected loads.
Maintenance Bypass Available
Maintenance bypass helps simplify service and maintenance while supporting power continuity when properly configured.
3-Stage Extendable Charging Design
The 3-stage extendable charging design helps optimize battery charging performance and supports different battery configurations.
Adjustable Battery Numbers
Battery numbers can be adjusted according to system configuration, backup time, and project requirements.
Standard and Long-Run Battery Options
Standard models provide built-in battery backup, while long-run models support external batteries for extended runtime applications.
Multiple Communication Interfaces
SNMP, USB, and RS-232 communication options support local monitoring, remote management, and integration with power management systems.
LCD Status Display
The LCD display provides UPS status, load level, battery level, input/output voltage, discharge time, and fault information for easier operation and monitoring.
Specifications
| MODEL | 3/1-10K (L) | 3/1-15K (L) | 3/1-20K (L) | 3/1-30K (L) | |
| PHASE | 3-phase in / 1-phase out | ||||
| CAPACITY | 10000 VA / 8000 W | 15000 VA / 12000 W | 20000 VA / 16000 W | 30000 VA / 24000 W | |
| INPUT | |||||
| Nominal Voltage | 3 x 400 VAC (3Ph+N) | ||||
| Voltage Range | 190-520 VAC (3-phase) @ 50% load ; 305-478 VAC (3-phase) @ 100% load | ||||
| Frequency Range | 46~54Hz or 56~64Hz | ||||
| Power Factor | ≧ 0.99 @ 100% Load | ||||
| THDi | < 6% @ 100% load | ||||
| OUTPUT | |||||
| Output Voltage | 208/220/230/240VAC | ||||
| AC Voltage Regulation (Batt. Mode) | ± 1% | ||||
| Frequency Range (Synchronized Range) | 46~54Hz or 56~64Hz | ||||
| Frequency Range (Batt. Mode) | 50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz | ||||
| Current Crest Ratio | 3:1 (max.) | ||||
| Harmonic Distortion | ≦ 2 % THD (Line ar Load); ≦ 5 % THD (Non-linear Load) | ||||
| Transfer Time | AC Mode to Batt. Mode | Zero | |||
| Inverter to Bypass | Zero | ||||
| Waveform (Batt. Mode) | Pure Sinewave | ||||
| EFFICIENCY | |||||
| AC Mode | 91.5% | 91.8% | 91.8% | 92.1% | |
| ECO Mode | 97% | 97% | 97% | 97% | |
| Battery Mode | 87% | 88% | 88% | 89% | |
| BATTERY | |||||
| Standard Model | Battery Type | 12 V / 9 Ah | |||
| Numbers | 20 pcs (18 – 20 pcs adjustable)* | 20 pcs (18 – 20 pcs adjustable)* x 2 strings | 20pcs (18-20pcs adjustable)* x3 strings | ||
| Typical Recharge Time | 9 hours recover to 90% capacity | 9 hours recover to 90% capacity | |||
| Charging Current (max.) | 1A | 2A | 2A | 4A | |
| Charging Voltage | 273 VDC ± 1% (Based on 20pcs batteries) | ||||
| Long-run Model | Battery Type | Depending on applications | |||
| Numbers | |||||
| Charging Current (max.) | 4A | 8A | 8A | 12A | |
| Charging Voltage | 273 VDC ± 1% (Based on 20pcs batteries) | ||||
| INDICATORS | |||||
| LCD Display | UPS status, Load level, Battery level, Input/Output voltage, Discharge timer, and Fault conditions | ||||
| ALARM | |||||
| Battery Mode | Sounding every 4 seconds | ||||
| Low Battery | Sounding every second | ||||
| Overload | Sounding twice every second | ||||
| Fault | Continously sounding | ||||
| PHYSICAL | |||||
| Standard Model | Dimension, D x W x H (mm) | 592 x 250 x 576 | 815 x 250 x 826 | 815 x 300 x 1000 | |
| Net Weight (kgs) | 83 | 164 | 164 | 234 | |
| Long-run Model | Dimension, D x W x H (mm) | 592 x 250 x 576 | 592 x 250 x 576 | 592 x 250 x 576 | 815 x 250 x 826 |
| Net Weight (kgs) | 28 | 40 | 40 | 64 | |
| ENVIRONMENT | |||||
| Operating Humidity | 0-95 % RH @ 0- 40°C (Non-condensing) | ||||
| Noise Level | Less than 58dB @ 1 Meter | Less than 60dB @1 Meter | Less than 65dB @1 Meter | ||
| MANAGEMENT | |||||
| Smart RS-232 / USB | Supports Windows2 2000/2003/XP/Vista/2008, Windows2 7/8/10, Linux and MAC | ||||
| Optional SNMP | Power management from SNMP manager and web browser | ||||
| * L means long-run model. | |||||
| **When using internal batteries from 18-19, the unit will de-rate according to below formula: P = PRating x N/20. | |||||
| **Derate capacity to 90% of capacity when the output voltage is adjusted to 208VAC. | |||||
| Product specifications are subject to change without further notice. | |||||
Applications
Server Rooms
Provides reliable backup power for servers, storage systems, switches, firewalls, and small-to-medium IT infrastructure.
Network and Communication Rooms
Suitable for routers, switches, telecom equipment, communication devices, and network infrastructure requiring stable single-phase output power.
Telecom Systems
Supports telecom equipment rooms, transmission systems, edge network sites, and communication infrastructure.
Industrial Control Systems
Helps protect PLC systems, industrial PCs, monitoring devices, control room equipment, and automation-related electronics.
Medical IT Equipment
Suitable for healthcare IT rooms, medical workstations, diagnostic support systems, and selected sensitive medical electronics.
Financial and Banking Systems
Provides backup power for bank IT rooms, payment systems, transaction equipment, branch infrastructure, and financial service systems.
Commercial IT Infrastructure
Protects office servers, network cabinets, VoIP systems, business systems, and other critical office electronics.
Security and Surveillance Systems
Supports CCTV systems, NVRs, access control systems, alarm systems, and security network equipment.
Retail and POS Systems
Provides backup power for POS terminals, payment devices, store networks, and security equipment in retail and service environments.
Long Backup Time Applications
Adjustable battery numbers and long-run battery configurations make it suitable for projects requiring extended backup time.
Frequently Asked Questions
What is this online UPS used for?
This UPS is designed to provide backup power and power protection for servers, network equipment, telecom systems, industrial control devices, medical IT equipment, financial systems, security systems, and other critical single-phase loads.
What does 3P/1P mean?
3P/1P means 3-phase input and single-phase output. It is useful when a facility has 3-phase mains power but the protected equipment requires single-phase output power.
Does this UPS also support 1P/1P operation?
Yes. This UPS supports both 3P/1P and 1P/1P operation, depending on model configuration and site power requirements.
What capacity range is available?
This UPS is available in 10kVA, 15kVA, 20kVA, and 30kVA, with output power ratings of 8kW, 12kW, 16kW, and 24kW.
Does this UPS provide pure sine wave output?
Yes. It provides pure sine wave output, making it suitable for servers, network devices, telecom equipment, industrial control systems, medical IT systems, and sensitive electronics.
Does this UPS have zero transfer time?
Yes. As a true online double-conversion UPS, it provides zero transfer time during mains power interruptions.
Does this UPS support ECO mode?
Yes. ECO mode is available to improve operating efficiency when input power quality is stable and suitable.
Can this UPS work with a generator?
Yes. It is generator compatible and can work with generator input in suitable backup power systems.
Does this UPS support maintenance bypass?
Yes. Maintenance bypass is available, helping simplify service and maintenance while supporting power continuity when properly configured.
Does this UPS support long backup time?
Yes. Standard and long-run battery configurations are available. Adjustable battery numbers and extendable charging design help support different backup time requirements.
What communication options are available?
The UPS supports SNMP, USB, and RS-232 communication options for monitoring, management, and integration with power management systems.
What information is needed to choose the right model?
To recommend the right model, the following information is usually required: load capacity, input/output voltage, phase requirement, backup time, battery configuration, generator availability, monitoring requirements, installation environment, and whether 3P/1P or 1P/1P operation is required.