Online Double-Conversion Technology
Double-conversion online topology provides continuous power conditioning and stable output power for sensitive IT and network equipment.
Compact 2U Rack-Mount Design
The 2U rack-mounted chassis is designed for server racks, network cabinets, telecom rooms, and space-limited IT environments.
Internal Battery Configuration
Standard models include internal batteries, providing short-term backup power for safe shutdown and temporary operation during outages.
Pure Sine Wave Output
Pure sine wave output helps protect servers, switches, storage devices, communication equipment, and other sensitive electronics.
Wide Input Voltage Range
The wide input voltage range of 90–300VAC helps the UPS operate reliably in unstable mains power environments.
High Input Power Factor
Input power factor ≥0.99 helps improve electrical efficiency and reduce impact on the upstream power system.
Precise Output Voltage Regulation
Output voltage regulation of ±1% provides stable power for connected critical loads.
Zero Transfer Online Operation
Online double-conversion operation provides continuous output power without transfer interruption during mains power disturbances.
Strong Overload Capability
The UPS supports short-term overload conditions, including 105%–125%, 125%–150%, and over 150% protection response levels.
LCD and LED Display
LCD and LED display options show key UPS information such as mains status, battery status, load level, battery level, operation mode, input voltage, frequency, and health status.
RS-232 Communication
Standard RS-232 communication supports UPS monitoring and system communication.
Optional Monitoring Cards
Optional NMC card, MODBUS-485 card, USB card, and dry contact card support remote monitoring, industrial communication, and alarm integration.
Quiet Operation
With noise level below 55dB at 1 meter, the UPS is suitable for offices, network rooms, and small IT environments.
Specifications
| MODEL | C1KR | C1KRL | C2KR | C2KRL | C3KR | C3KRL |
| CAPACITY | 1KVA/800W | 2KVA/1.6KW | 3KVA/2.4KW | |||
| TOPOLOGY | Double Conversion Online UPS | |||||
| PHASE | Single Phase Input Single Phase Output | |||||
| INPUT | ||||||
| Input Wiring | L/N+PE | |||||
| Nominal Voltage | 208/220/230/240VAC | |||||
| Input Voltage Range | 90~300VAC | |||||
| Frequency Range | 40Hz-70Hz | |||||
| Input Power Factor | ≥0.99 | |||||
| OUTPUT | ||||||
| Output Wiring | L/N+PE | |||||
| Output Voltage | 208/220/230/240VAC | |||||
| Voltage Regulation | ±1% | |||||
| Output Frequency | 50/60 ± 4Hz (Sync Mode) / 50/60 Hz ± 0.1% (Free Run) | |||||
| Output Waveform | Pure Sine Wave | |||||
| Output Distortion (THDV%) | <2%(Linear Load), <7%(None-Linear Load) | |||||
| Over Load Capability | 1Min@105%~125%, 30Sec.@125%~150%, 0.5Sec.@>150% | |||||
| EFFICIENCY | ||||||
| AC Mode | 88% | 89% | 90% | |||
| Battery Mode | 86% | 87% | 88% | |||
| BATTERY & CHARGER | ||||||
| Battery Voltage | 24VDC | 36VDC | 48VDC | 72VDC | 72VDC | 96VDC |
| Battery Capacity | 12V/7Ah x 2pcs | External | 12V/7Ah x 4pcs | External | 12V/7Ah x 6pcs | External |
| Backup Time | ≥8mins @ Half Load, ≥3mins @ Full Load (Standard) | |||||
| Charging Current (max.) | 1A | 4A | 1A | 4A | 1A | 4A |
| PHYSICAL | ||||||
| Chassis Style | Rack-Mounted | |||||
| Rack Dimension | L-3KR: 438mm(W) x 88mm(2U)(H) x 500mm(D) Include Internal Battery | |||||
| Other Models: 438mm(W) x 88mm(2U)(H) x 360mm(D) | ||||||
| Weight (kg) | 13 | 8.5 | 18.5 | 11.2 | 21.9 | 12 |
| HMI | ||||||
| LED Display | Mains / Battery Status, Load Level, Battery Level, Operation Mode | |||||
| LCD Display | Input Mains Voltage, Frequency, Load level, Operation Mode, Health Status | |||||
| Standards Communication | RS232 port | |||||
| Optional Extension Card | NMC Card, MODBUS-485 Card, USB Card, Dry Contact Card | |||||
| ENVIRONMENT | ||||||
| Temperature range | 0~40℃ | |||||
| Relative Humidity | 0-98% (Non-condensing) | |||||
| Noise Level | <55dB @ 1 meters | |||||
| * Product specifications are subject to change without further notice. | ||||||
Applications
Server Racks
Provides backup power for rack-mounted servers, switches, firewalls, storage devices, and IT equipment.
Network Cabinets
Suitable for routers, switches, communication devices, and network infrastructure installed in standard cabinets.
Small Server Rooms
Helps protect small server rooms, branch IT rooms, and local business infrastructure from power interruptions.
Telecom Equipment
Supports telecom devices, communication equipment, and network systems requiring clean and stable power.
Security Systems
Provides backup power for NVRs, CCTV systems, access control devices, and security network switches.
Edge IT Infrastructure
Suitable for edge computing sites, remote IT cabinets, and distributed network equipment.
Office IT Systems
Protects office servers, NAS storage, VoIP systems, firewalls, and business-critical IT equipment.
Frequently Asked Questions
What is this rack-mount online UPS used for?
It is designed to provide reliable backup power and power protection for servers, network devices, storage systems, telecom equipment, security systems, and small IT infrastructure.
What capacity range is available?
The UPS is available in 1kVA, 2kVA, and 3kVA capacities, with output power ratings of 800W, 1.6kW, and 2.4kW.
Does this UPS include internal batteries?
Yes. The standard models include internal batteries for short-term backup power. Typical backup time is ≥8 minutes at half load and ≥3 minutes at full load, depending on load and battery condition.
What is the advantage of online double-conversion topology?
Online double-conversion topology provides continuous power conditioning and stable output power, helping protect connected equipment from outages, voltage fluctuations, frequency instability, and other power disturbances.
Does this UPS provide pure sine wave output?
Yes. It provides pure sine wave output, making it suitable for servers, network equipment, storage systems, and sensitive electronic devices.
What communication options are available?
The UPS supports standard RS-232 communication and optional NMC, MODBUS-485, USB, and dry contact cards for monitoring and integration.
Is this UPS suitable for data centers?
It is suitable for small server rooms, network racks, edge IT cabinets, and branch IT systems. For larger data centers, a higher-capacity online UPS or modular UPS may be more suitable.
What information is needed to choose the right model?
To choose the right model, provide the equipment list, total load, input/output voltage, required backup time, rack space, monitoring requirements, and whether internal or external battery configuration is preferred.