3P/3P High Frequency Online UPS 30KVA 40KVA

This 3P/3P online UPS 30–40kVA provides reliable double-conversion power protection for data rooms, server rooms, telecom facilities, industrial control systems, medical IT infrastructure, financial systems, commercial buildings, and other critical three-phase loads. With 3-phase input and 3-phase output, pure sine wave output, input power factor ≥0.99, output power factor 0.9, output voltage regulation ±1%, and zero transfer time, it helps protect sensitive equipment from outages, voltage fluctuations, surges, frequency instability, and power quality problems.

Designed for higher-capacity three-phase applications, this UPS supports wide input voltage range, ECO mode with up to 96% efficiency, standard battery and long-run external battery configurations, LCD status display, smart RS-232/USB communication, optional SNMP monitoring, and audible alarm functions. It is suitable for projects requiring stable three-phase backup power, extended runtime options, and professional power management.

Features

True Online Double-Conversion

Online double-conversion technology provides continuous power conditioning and stable output power for critical three-phase loads.

3-Phase Input / 3-Phase Output

The UPS supports 3-phase input and 3-phase output, making it suitable for facilities where both utility power and protected loads require three-phase power.

30–40kVA Capacity Range

Available in 30kVA and 40kVA, with output power ratings of 27kW and 36kW.

Pure Sine Wave Output

Pure sine wave output provides clean and stable power for servers, telecom systems, industrial controllers, medical IT systems, and sensitive electronic equipment.

Output Power Factor 0.9

Output power factor 0.9 delivers strong active power capacity for modern IT, telecom, industrial, and critical infrastructure loads.

High Input Power Factor

Input power factor ≥0.99 at 100% load helps improve power efficiency and reduce impact on upstream electrical systems.

Wide Input Voltage Range

The UPS supports a wide input voltage range, helping maintain operation in unstable mains power environments and reducing unnecessary battery discharge.

Stable Output Voltage

Output voltage regulation of ±1% helps provide stable and reliable three-phase output power for connected equipment.

Zero Transfer Time

Online operation provides zero transfer time from AC mode to battery mode, helping prevent interruption to critical loads.

Low Harmonic Distortion

Output harmonic distortion is controlled at ≤2% for linear loads and ≤5% for non-linear loads, helping provide cleaner output power.

ECO Mode for Energy Saving

ECO mode efficiency can reach up to 96%, helping reduce energy consumption when mains power quality is stable.

Standard and Long-Run Battery Options

Standard models include internal battery configurations, while long-run models support external batteries for extended backup time.

External Battery Support

Long-run models allow external battery capacity to be configured according to required runtime and load demand.

LCD Status Display

The LCD panel provides UPS status, load level, battery level, input/output voltage, discharge timer, and fault information.

Smart RS-232 / USB Communication

Smart RS-232 and USB communication support UPS monitoring and power management with compatible systems.

Optional SNMP Monitoring

Optional SNMP enables network-based UPS monitoring and power management through SNMP manager or web browser.

Audible Alarm System

Audible alarms provide warnings for battery mode, low battery, overload, and fault conditions.

High Efficiency Operation

AC mode efficiency reaches 92.1%, helping reduce operating losses in continuous power protection applications.

Specifications

MODELLP-3C3-30K/LLP-3C3-40K/L
PHASE3 phase in / 3 phase out
CAPACITY*30000 VA / 27000W40000 VA / 36000W
INPUT
Nominal Voltage3×400 VAC (3Ph+N)
Voltage Range190-520 VAC(3-phase)@50%load, 305-478 VAC(3-phase)@100%load
Frequency Range46~54 Hz or 56~64 Hz
Power Factor≧ 0.99 @ 100% load
OUTPUT
Output Voltage3×400 VAC (3Ph+N)
AC Voltage Regulation(Batt.Mode)±1%
Frequency Range(Synchronized Range)46~54Hz or 56~64 Hz
Frequency Range(Batt.Mode)50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz
Current Crest Ratio3:1(max.)
Harmonic Distortion≦2%THD(Linear Load); ≦5%THD (Non-linear Load)
Transfer TimeAC Mode to Batt.ModeZero
Inverter to BypassZero
Waveform(Batt.Mode)Pure Sinewave
EFFICIENCY
AC Mode92.1%
ECO Mode96.0%
Battery Mode89.0%
BATTERY
Standard ModelBattery Type12V / 9Ah
Numbers20 pcs (18 – 20 adjustable)*x 3 strings
Typical Recharge Time9 hours recover to 90% capacity
Charging Current(max.)4A
Charging Voltage273 VDC±1%
Long-run ModelBattery TypeDepending on the capacity of external batteries
Numbers
Charging Current(max.)12A
Charging Voltage273VDC±1%
INDICATORS
LCD PanelUPS status,Load level,Battery level,Input/Output voltage,Discharge timer,and Fault
ALARM
Battery ModeSounding every 4 seconds
Low BatterySounding every second
OverloadSounding twice every second
FaultContinuously sounding
PHYSICAL
Standard ModelDimension,DxWxHmm)815 x 300 x 1000
Net Weight(kgs)233.5
Long-run ModelDimension,DxWxH(mm)815 x 250 x 826
Net Weight(kgs)64
ENVIRONMENT
Operation Humidity0-95%RH @ 0-40℃ (non-condensing)
Noise LevelLess than 60dB @1 Meter
MANAGEMENT
Smart RS-232/USBSupports Windows®2000/2003/XP/Vista/2008,Windows®7/8/10,Linux and MAC
Optional SNMPPower management from SNMP manager and web browser
*When using batteries from 18-19, the unit will de-rate according to below formula: P=Prating x N/20.
*Product specifications are subject to change without further notice.

Applications

Data Rooms and Server Rooms

Provides stable three-phase backup power for servers, storage systems, switches, firewalls, and IT infrastructure.

Small and Medium Data Centers

Suitable for critical IT environments requiring reliable three-phase online power protection.

Telecom Facilities

Supports communication rooms, telecom systems, transmission equipment, and network infrastructure.

Industrial Control Systems

Helps protect PLC systems, industrial PCs, monitoring devices, control room equipment, and automation-related electronics.

Medical IT Systems

Suitable for healthcare IT rooms, medical workstations, diagnostic support systems, and selected sensitive medical electronics.

Financial and Banking Systems

Provides backup power for bank IT rooms, payment systems, transaction equipment, branch infrastructure, and security systems.

Commercial Buildings

Supports centralized backup power for office IT rooms, communication systems, security systems, and business-critical equipment.

Security and Surveillance Systems

Protects CCTV systems, NVRs, access control systems, alarm systems, and security network equipment.

Long Backup Time Projects

Long-run external battery configurations make it suitable for sites requiring extended backup time or unstable grid conditions.

Frequently Asked Questions

What is this 3P/3P online UPS used for?

This UPS is designed to provide reliable backup power and power protection for servers, network equipment, telecom systems, industrial control devices, medical IT systems, financial systems, and other critical three-phase loads.

What does 3P/3P mean?

3P/3P means 3-phase input and 3-phase output. It is suitable for applications where both the incoming power supply and protected equipment require three-phase power.

What capacity range is available?

This UPS is available in 30kVA and 40kVA, with output power ratings of 27kW and 36kW.

What is the output power factor?

The UPS provides an output power factor of 0.9, delivering strong active power capacity for critical three-phase loads.

Does this UPS provide pure sine wave output?

Yes. It provides pure sine wave output, making it suitable for servers, telecom equipment, industrial control systems, medical IT equipment, and sensitive electronics.

Does this UPS have zero transfer time?

Yes. As an online double-conversion UPS, it provides zero transfer time during mains power interruptions.

Does this UPS support ECO mode?

Yes. ECO mode can improve efficiency up to 96% when input power quality is stable and suitable.

Does this UPS support long backup time?

Yes. Long-run models support external batteries, allowing backup time to be configured according to load and runtime requirements.

What battery configuration does this UPS use?

The standard model uses 12V / 9Ah batteries, typically with 20 batteries per string and 3 strings. Long-run models can be configured with external batteries according to project requirements.

What communication options are available?

The UPS supports smart RS-232 and USB communication, with optional SNMP for network-based monitoring and power management.

Is this UPS suitable for data centers?

It is suitable for data rooms, server rooms, small and medium data centers, telecom rooms, and critical three-phase IT infrastructure. For larger or scalable data centers, a modular UPS may be more suitable.

What information is needed to choose the right model?

To recommend the right model, the following information is usually required: load capacity, input/output voltage, backup time, battery configuration, installation environment, monitoring requirements, and whether standard or long-run battery configuration is needed.