Features
Low Frequency Double-Conversion Online Design
Low frequency double-conversion online design provides continuous power conditioning and stable output power for high-capacity 3-phase critical loads.
3-Phase Input / 3-Phase Output
The UPS supports 3-phase input and 3-phase output, making it suitable for data centers, industrial facilities, commercial buildings, and critical infrastructure requiring three-phase power protection.
High-Capacity Power Range
Available in 60kVA, 80kVA, 100kVA, and 120kVA, this UPS supports medium-to-large critical power applications with nominal output power from 48kW to 96kW.
Pure Sine Wave Output
Pure sine wave output provides clean and stable power for servers, telecom systems, industrial equipment, healthcare systems, and sensitive electronic loads.
Zero Transfer Time
With online double-conversion operation, the UPS provides 0ms transfer time, helping maintain uninterrupted power during mains power disturbances.
Stable Output Voltage
Output voltage stability of ±1% under steady-state load helps ensure reliable operation for connected critical equipment.
Wide Input Voltage Support
The UPS supports 220/380/400/415/440VAC input options with wide voltage tolerance, improving adaptability in different three-phase power environments.
Flexible DC Voltage Design
Different models support 384VDC, 432VDC, or 480VDC battery systems, allowing suitable battery configuration according to capacity and project requirements.
VRLA Battery Support
The UPS supports maintenance-free lead-acid battery systems, making it suitable for standard backup and long-runtime external battery configurations.
Strong Overload Capability
The UPS supports overload operation, including 110% for 300 minutes, 125% for 10 minutes, and 150% for 1 minute, helping improve reliability during temporary load impact conditions.
High System Efficiency
System efficiency up to 93% helps reduce energy loss and supports long-term operation in professional power environments.
Bypass Operation
Built-in bypass operation helps improve power continuity and supports system operation under specific overload or maintenance conditions.
Parallel and Redundancy Support
The UPS supports serial hot backup, redundancy, and parallel operation, making it suitable for applications requiring higher reliability or future capacity expansion.
Comprehensive Protection Functions
Protection functions include input protection, output protection, battery protection, temperature protection, and hardware fault protection to help improve overall system safety.
Dry Contact Interface
Dry contact interface provides alarm and status signal integration for external monitoring systems or facility management platforms.
EPO Interface
The Emergency Power Off interface allows fast shutdown in emergency situations when connected to the proper external control mechanism.
RS232 Communication
RS232 communication supports local monitoring, system communication, and basic UPS management.
LED and LCD Display
LED indicators show input, inverter, bypass, and battery status. The LCD display provides input/output voltage, frequency, load percentage, battery voltage, and internal status information.
Forced-Air Cooling
Forced-air cooling helps maintain stable thermal performance during continuous high-capacity operation.
IP21 Protection
IP21 protection provides basic protection for indoor installation environments.
Specifications
| Model | 3C3-60KL | 3C3-80KL | 3C3-100KL | 3C3-120KL | |
| Capacity | 60KVA | 80KVA | 100KVA | 120KVA | |
| Nominal Capacity | 48KW | 64KW | 80KW | 96KW | |
| Phase | 3 phase in 3 phase out | ||||
| Work Mode | Low frequency double conversion pure online | ||||
| Power Factor | >0.8 | ||||
| Display | LED | Including the state of input, inverter, bypass and battery | |||
| LCD | Input & output voltage, frequency, battery voltage, present of loads, internal humidity | ||||
| Rectifier | Input Voltage | 220V/380V/400V/415V/440VAC ±30% 3 phase four wires input | |||
| Input Frequency | 50/60hz ± 10% | ||||
| Wave Form | Pure sine wave | ||||
| Battery | Free-maintenance, Lead-acid battery | ||||
| Inverter | Nominal Voltage | 220/380/400/415/440VAC | |||
| Output Voltage Stability | ±1% (steady-state load) ±5% (load fluctuations) | ||||
| Frequency Stability | 50/60hz load ± 0.5% | ||||
| Crest Factor | >3:1 | ||||
| THD | Pure sine wave <3% (linear load) | ||||
| Overload Capacity | 110% 300mins,125% 10mins, 150% 1mins | ||||
| Efficiency | 93% | ||||
| Bypass | Rated Voltage | For single phase L1: 220VAC (or 230VAC), For three phase: 380VAC(or 400VAC) | |||
| Bypass Voltage Range | 220/380/415/440 ± 20% (10% 15% 20% adjustable) | ||||
| Rated Frequency | 50/60hz | ||||
| Bypass Frequency Range | ±20% (±1% to ±5% adjustable) | ||||
| Transfer Time | 0ms | ||||
| DC Voltage | 384VDC | 432VDC | 480VDC | ||
| Protection | Input Protection | Overrun high or low input, overrun frequency | |||
| Output Protection | Overcurrent, short circuit, low power factor | ||||
| Battery Protection | Over charge, over discharge protection | ||||
| Temperature Protection | Environmental overheating, inverter over-temperature protection | ||||
| Hardware Fault Protection | Auxiliary power anomaly, circuit breaker tripping, fuses disconnect and the power device over-current voltage protection | ||||
| System Parameter | Ambient Temperature | 0-40℃ | |||
| Cooling Mode | forced ventilation | ||||
| Communication Interface | RS232, dry contact interface, EPO interface | ||||
| Redudancy & Parallel | Serial hot backup or redundancy & parallel | ||||
| Surge Capacity | (0/700µs,5KV) 8/20µs, 20KVA | ||||
| Protection Class | IP21 | ||||
| Security Capacity | Input and output electrical resistance to ground 3000VAC, leaking less than 3.5MA, insulation resistance>2Mw(500VDC) | ||||
| Noise dB | 58dB-70dB | ||||
| Dimension (mm) | 800*745*1400 | 1070*745*1400 | |||
| N.W (kgs) | 497 | 556 | 756 | 901 | |
| G.W (kgs) | 574 | 633 | 856 | 1001 | |
| * Product specifications are subject to change without further notice. | |||||
Applications
Data Centers
Provides stable 3-phase backup power for servers, storage systems, network equipment, and critical IT infrastructure.
Industrial Facilities
Suitable for industrial control systems, automation equipment, PLC systems, monitoring platforms, and production support infrastructure.
Telecom Facilities
Supports telecom rooms, communication hubs, transmission systems, network infrastructure, and high-capacity communication equipment.
Healthcare Facilities
Helps protect healthcare IT rooms, diagnostic support systems, laboratory equipment, and selected critical medical infrastructure.
Financial Institutions
Provides backup power for bank data rooms, payment systems, transaction platforms, security systems, and financial IT infrastructure.
Commercial Buildings
Suitable for centralized power protection in commercial buildings, office IT rooms, communication systems, security infrastructure, and building control systems.
Emergency and Public Safety Facilities
Supports emergency operation centers, dispatch systems, communication rooms, surveillance systems, and mission-critical response infrastructure.
Education and Research Facilities
Protects campus IT rooms, laboratories, research platforms, testing equipment, and network infrastructure.
Long Backup Time Projects
External VRLA battery support and high-voltage DC battery configurations make it suitable for applications requiring extended backup time.
Frequently Asked Questions
What is this low frequency 3-phase online UPS used for?
This UPS is designed to provide high-capacity backup power and power protection for data centers, industrial systems, telecom facilities, healthcare infrastructure, financial systems, commercial buildings, and other critical 3-phase loads.
What capacity range is available?
This UPS is available in 60kVA, 80kVA, 100kVA, and 120kVA models, with nominal output power from 48kW to 96kW.
What does 3P/3P mean?
3P/3P means 3-phase input and 3-phase output. It is suitable for sites where both the power supply and protected loads require three-phase power.
What is the difference between this model and the 10–40kVA version?
The 10–40kVA version is suitable for medium-size three-phase power applications, while this 60–120kVA version is designed for higher-capacity critical loads such as larger data rooms, industrial facilities, telecom infrastructure, and commercial power systems.
What is the difference between low frequency UPS and high frequency UPS?
A low frequency UPS is generally designed for robust critical power protection and demanding electrical environments. It is often preferred for applications requiring stronger overload capability, better load adaptability, and long-term stability.
Does this UPS provide pure sine wave output?
Yes. It provides pure sine wave output, making it suitable for sensitive electronic equipment, industrial systems, telecom equipment, healthcare systems, and critical infrastructure loads.
Does this UPS have zero transfer time?
Yes. As an online double-conversion UPS, it provides 0ms transfer time, helping protect critical loads from interruption during mains power disturbances.
What battery voltage does this UPS use?
Depending on the model, this UPS supports 384VDC, 432VDC, or 480VDC battery systems. Battery configuration should be selected according to model capacity, backup time, and project requirements.
Does this UPS support external batteries?
Yes. It supports external maintenance-free lead-acid battery systems, making it suitable for long-runtime backup power applications.
Does this UPS support parallel operation?
Yes. It supports serial hot backup, redundancy, and parallel operation, depending on project configuration and system design.
What communication interfaces are available?
The UPS supports RS232 communication, dry contact interface, and EPO interface for monitoring, alarm integration, and emergency shutdown control.
What protection functions are included?
The UPS includes input protection, output protection, battery protection, temperature protection, hardware fault protection, short-circuit protection, overload protection, and over-temperature protection.
Is this UPS suitable for industrial applications?
Yes. It is suitable for industrial control rooms, automation systems, monitoring equipment, PLC systems, and other industrial environments requiring stable high-capacity 3-phase backup power.
What information is needed to choose the right model?
To recommend the right model, the following information is usually required: load capacity, input/output voltage, backup time, battery configuration, installation environment, redundancy or parallel requirement, communication interface needs, and site power conditions.