1P/1P or 3P/1P or 3P/3P High Frequency Modular Online UPS 10KAV to 100KVA

This rack/tower convertible online UPS provides reliable double-conversion power protection for servers, network equipment, telecom systems, industrial control devices, medical IT systems, security equipment, and other critical loads. With true online technology, DSP control, output power factor 1.0, pure sine wave output, ECO mode, generator compatibility, and 50Hz/60Hz frequency converter mode, it delivers stable and efficient backup power for demanding applications.

Designed with a standard 19-inch form factor, hot-swappable modular connector box, adjustable battery configuration, and parallel operation support, this UPS offers flexible installation, easier maintenance, and scalable capacity expansion. Multiple units can operate in parallel, with common battery support available to help reduce system cost and simplify backup power design.

Features

True Online Double-Conversion

True online double-conversion technology provides continuous power protection and helps isolate connected equipment from mains power disturbances.

DSP Technology

DSP control improves system reliability, response accuracy, and power management performance for critical applications.

Output Power Factor 1.0

Output power factor 1.0 delivers more usable active power, helping support modern servers, network equipment, and sensitive electronic loads.

Rack/Tower Convertible Design

The standard 19-inch form factor supports both rack-mounted and tower installation, providing greater flexibility for server rooms, network cabinets, and equipment rooms.

Hot-Swappable Modular Connector Box

The modular connector box design allows easier power expansion, installation, and maintenance. Power modules can be removed from the cabinet without disconnecting wires, helping reduce service complexity.

Parallel Operation Support

Multiple UPS units can operate in parallel to increase system capacity or improve redundancy, making the UPS suitable for scalable power protection projects.

Common Battery Support

Parallel systems can share common battery packs, helping reduce system cost and simplify battery configuration while maintaining backup performance.

Adjustable Battery Design

Battery quantity can be adjusted according to different power demands and backup time requirements, offering greater flexibility for project configuration.

50Hz/60Hz Frequency Converter Mode

Frequency converter mode allows the output frequency to be locked at 50Hz or 60Hz, supporting power-sensitive equipment and special application requirements.

ECO Mode for Energy Saving

ECO mode improves operating efficiency and helps reduce energy consumption when power conditions are suitable.

Emergency Power Off Function

The EPO function allows the UPS system to be shut down quickly in emergency situations when connected to the proper control mechanism.

Generator Compatible

Generator compatibility allows the UPS to accept generator power and continue supplying stable output power to connected loads.

LCD/LED Status Display

The display provides UPS status information such as load level, battery level, input/output voltage, discharge time, and fault conditions.

Optional SNMP Monitoring

Optional SNMP support enables network-based monitoring and power management through SNMP manager or web browser.

Specifications

MODEL3/3-10K3/1-10K1/1-10K
PHASE3 phase in / 3 phase out3 phase in / 1 phase out1 phase in / 1 phase out
CAPACITY10000 VA / 10000 W10000 VA / 10000 W10000 VA / 10000 W
PARALLEL CAPABILITY101010
INPUT
Nominal Voltage3 x 360VAC/380VAC/
400VAC/415VAC (3Ph+N+PE)
3 x 360VAC/380VAC/
400VAC/415VAC (3Ph+N+PE)
208VAC/220VAC/230VAC
/240VAC (1Ph+N+PE)
Voltage Range190-520 VAC (3-phase) @ 50% load
305-478 VAC (3-phase) @ 100% load
110-300 VAC @ 50% load
176-276 VAC @ 100% load
Frequency Range40 Hz ~ 70 Hz
Power Factor≧ 0.99 @ 100% load
THDi< 4% @ full linear load
OUTPUT
Output Voltage360VAC/380VAC/400VAC/
415VAC (3Ph+N)
208*/220/230/240VAC (L+N)208*/220/230/240VAC (L+N)
AC Voltage Regulation (Batt. Mode)± 1%
Frequency Range (Synchronized Range)46~54Hz or 56~64Hz
Frequency Range (Batt. Mode)50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz
Current Crest Ratio3:1 (max.)
Harmonic Distortion≦ 2% THD (Linear Load) ; ≦ 3% THD (Non-linear Load)
Transfer TimeAC Mode to Batt. ModeZero
Inverter to BypassZero
Waveform (Batt. Mode)Pure Sinewave
EFFICIENCY
AC Mode94%94%93.5%
ECO Mode97%97%97%
Battery ModeAt Full Load93%92.5%92%
Peak93.5%93%92.5%
BATTERY CHARGER
Battery Voltage± 12V / 9 Ah
Battery Numbers16 ~ 20 pcs (adjustable) x 216 ~ 20 pcs (adjustable) x 216 ~ 20 pcs (adjustable) x 2
Nominal Voltage+/-192V (12V x 32 pcs)+/-192V (12V x 32 pcs)+/-192V (12V x 32 pcs)
Maximum Voltage+/- 240V (12V x 40 pcs)+/- 240V (12V x 40 pcs)+/- 240V (12V x 40 pcs)
Minimum Voltage+/-192V (12V x 32 pcs)+/-192V (12V x 32 pcs)+/-192V (12V x 32 pcs)
Charging Voltage± 218V± 218V± 218V
Typical Recharging Time9 hours recover to 90% capacity
Charging Current± 4A
INDICATORS
LCD/LED DisplayUPS status, Load level, Battery level, Input/Output voltage, Discharge timer, and Fault conditions
PHYSICAL
Dimension, D x W x H(mm)678 x 418 x 129 [3U]
Net Weight (kgs)20.520.520.5
ENVIRONMENT
Operating Humidity0-95 % RH @ 0- 40°C (non-condensing)
Noise LevelLess than 55dB @ 1 MeterLess than 55dB @ 1 MeterLess than 55dB @ 1 Meter
MANAGEMENT
Smart RS-232/USBSupports Windows® 2000/2003/XP/Vista/2008/7/8/10, Linux and MAC
Optional SNMPPower management from SNMP manager and web browser
*Derate capacity to 90% of capacity when the output voltage is adjusted to 208VAC.
Product specifications are subject to change without further notice

Applications

Server Rooms

Provides stable backup power for servers, storage systems, switches, firewalls, and critical IT equipment.

Network Rooms

Suitable for routers, switches, communication equipment, and network infrastructure requiring reliable online power protection.

Telecom Systems

Supports telecom equipment, communication systems, and network devices that require clean and continuous power.

Industrial Control Systems

Helps protect PLC systems, industrial PCs, monitoring equipment, and control room devices from power interruptions and voltage disturbances.

Medical IT Equipment

Suitable for healthcare IT rooms, medical workstations, monitoring systems, and selected diagnostic support equipment.

Financial and Banking Systems

Provides backup power for bank IT rooms, payment systems, branch infrastructure, security systems, and transaction-related equipment.

Commercial Office IT Infrastructure

Supports office servers, network cabinets, VoIP systems, security devices, and business-critical electronics.

Security and Surveillance Systems

Helps maintain power for CCTV, NVR systems, access control devices, alarm systems, and security network equipment.

Education and Research Facilities

Suitable for computer labs, campus IT systems, laboratory equipment, and research data systems.

Frequently Asked Questions

What is this rack/tower online UPS used for?

This UPS is designed to provide reliable online power protection for servers, network equipment, telecom systems, industrial control devices, medical IT systems, financial equipment, security systems, and other critical loads.

What does rack/tower convertible design mean?

Rack/tower convertible design means the UPS can be installed either in a standard 19-inch rack or used as a tower unit. This provides flexibility for server rooms, network cabinets, offices, and equipment rooms.

What is the benefit of true online double-conversion technology?

True online double-conversion technology provides continuous power conditioning and stable output power, helping protect connected equipment from outages, voltage fluctuations, frequency instability, surges, and other power disturbances.

Does this UPS support parallel operation?

Yes. Multiple units can be connected in parallel to increase system capacity or improve redundancy, depending on the project design.

Can this UPS use a common battery system?

Yes. In parallel operation, multiple UPS units can share common battery packs, helping reduce battery system cost and simplify configuration while maintaining backup performance.

What is the advantage of output power factor 1.0?

Output power factor 1.0 means the UPS can deliver more usable active power. This helps improve capacity utilization and better supports modern IT and critical electronic equipment.

Does this UPS support generator power?

Yes. The UPS is generator compatible and can work with generator input in suitable backup power systems, helping provide stable power to connected loads.

What is ECO mode?

ECO mode is an energy-saving operating mode that helps improve efficiency when input power conditions are stable and suitable.

What is EPO function?

EPO stands for Emergency Power Off. It allows the UPS to be shut down quickly in emergency situations when connected to the proper external control system.

What information is needed to choose the right UPS configuration?

To recommend the right configuration, the following information is usually required: load capacity, input/output voltage, phase requirement, backup time, installation method, battery configuration, parallel requirement, generator status, monitoring needs, and future expansion plan.