This single-phase online UPS 6–10kVA provides reliable double-conversion power protection for server rooms, network infrastructure, telecom systems, medical IT equipment, industrial control devices, financial systems, and other critical loads. With true online technology, pure sine wave output, input power factor correction, output power factor 0.8, wide input voltage range, converter mode, generator compatibility, and zero transfer performance, it helps ensure stable and continuous power for demanding applications.

Designed for higher-load environments, this UPS supports adjustable charging current via LCD or software, emergency power off function, USB/RS-232 communication, optional SNMP monitoring, and flexible battery configuration. Long-run models and external battery packs are available for applications requiring extended backup time.

Features

True Online Double-Conversion

True online double-conversion technology provides stable, clean, and continuous power protection for critical equipment.

Higher Capacity Power Protection

Available in 6kVA and 10kVA models, this UPS is suitable for server rooms, network infrastructure, telecom systems, and higher-load applications.

Pure Sine Wave Output

Pure sine wave output provides stable power for sensitive electronic equipment, servers, communication systems, and critical devices.

Input Power Factor Correction

Input power factor correction helps improve energy efficiency and reduce electrical stress on the upstream power system.

Output Power Factor 0.8

Output power factor 0.8 provides reliable active power capacity for servers, telecom devices, medical IT systems, and industrial control loads.

Wide Input Voltage Range

Wide input voltage range helps maintain stable UPS operation in areas with unstable or fluctuating mains power.

Frequency Converter Mode

Converter mode allows the UPS to provide fixed 50Hz or 60Hz output for applications requiring specific frequency conditions.

Adjustable Charging Current

Charging current can be adjusted via LCD or software, helping support different battery configurations and backup time requirements.

Emergency Power Off Function

The EPO function allows the UPS system to be shut down quickly in emergency situations when connected to the proper external control mechanism.

Generator Compatible

Generator compatibility allows the UPS to accept generator input and continue delivering stable power to connected loads.

Flexible Battery Configuration

Standard battery and long-run battery configurations are available to support different runtime requirements.

LCD Status Display

The LCD display provides UPS status, load level, battery level, input/output voltage, discharge time, and fault information.

USB, RS-232, and Optional SNMP

USB and RS-232 communication are supported, with optional SNMP for remote monitoring and network-based power management.

External Battery Support

External battery packs can be configured for applications requiring longer backup time.

Specifications

MODEL6KR (L)10KR (L)
PHASESingle phase with ground
CAPACITY*6000 VA / 4800 W10000 VA / 8000 W
INPUT
Nominal Voltage208/220/230/240 VAC
Input Voltage Range110-300 VAC (Based on load at 50%) 176-300VAC (Based on load at 100%)
Frequency Range46~54 Hz or 56-64 Hz
Power Factor≧0.99 @ Nominall Voltage (100% load)
OUTPUT
Output Voltage208/220/230/240VAC
Voltage Regulation±1%
Frequency Range (Synchronized Range)46~54 Hz or 56-64 Hz
Frequency Range (Batt. Mode)50 Hz or 60 Hz ± 0.1 Hz
Current Crest Ratio3:1 (max.)
Harmonic Distortion≦ 3 % THD (Linear Load) ≦ 5 % THD (Non-linear Load)
Transfer TimeAC Mode to Batt. ModeZero
Inverter to BypassZero
Waveform (Batt. Mode)Pure Sinewave
EFFICIENCY
AC Mode92%93%
Battery Mode90%91%
BATTERY
Standard ModelBattery Type12V / 9Ah
Numbers16201620
Typical Recharge Time9 hours recover to 90% capacity
Charging Current (max.)1 A / 2 A (Adjustable)
Charging Voltage218.4 VDC±1%273 VDC±1%218.4 VDC±1%273 VDC±1%
Long-run Model*Battery TypeDepending on applications
Numbers16 ~ 20 pcs (Adjustable)
Charging Current (max.)1A/2A/4A/6A (Adjustable, 6A is only available for 16pcs batteries)
Charging Voltage218.4 VDC ±1% (Based on 16pcs batteries)
INDICATORS
LCD PanelUPS status, Load level, Battery level, Input/Output voltage, Discharge timer, and Fault conditions
ALARM
Battery ModeSounding every 4 seconds
Low BatterySounding every second
OverloadSounding twice every second
FaultContinuously sounding
PHYSICAL
Standard ModelDimension, DxWxH (mm)UPS Unit:
530x438x88 [2U]
Battery Pack:
668x438x88 [2U]
UPS Unit:
530x438x88 [2U]
Battery Pack:
580x438x133 [3U]
UPS Unit: 580x438x133 [3U]
Battery Pack: 580x438x133 [3U]
Net Weight (kgs)UPS Unit: 15
Battery Pack: 48
UPS Unit: 15
Battery Pack: 61
UPS Unit: 18
Battery Pack: 51
UPS Unit: 18
Battery Pack: 61
Long-run Model*Dimension, DxWxH (mm)530 x 438 x 88 [2U]580 x 438 x 133 [3U]
Net Weight (kgs)1518
ENVIRONMENT
Operation Humidity0-95 % RH @ 0-40℃ (non-condensing)
Noise LevelLess than 55dB @1 MeterLess than 58dB @1 Meter
MANAGEMENT
Smart RS-232/USBSupports Windows®2000/2003/XP/Vista/2008,Windows®7/8/10,Linux and MAC
Optional SNMPPower management from SNMP manager and web browser
* Long-run model is only available for 200/208/220/230/240VAC systems.
* Derate to 80% of capacity in Frequency converter mode and to 80% when the output voltage is adjusted to 100/200/208VAC.
* Product specifications are subject to change without further notice.

Applications

Server Rooms

Provides reliable backup power for servers, storage systems, switches, firewalls, and network equipment.

Network Infrastructure

Suitable for communication rooms, network cabinets, routers, switches, and telecom infrastructure.

Telecom Systems

Supports telecom devices, transmission equipment, network systems, and communication infrastructure requiring stable power.

Medical IT Systems

Protects healthcare IT rooms, medical workstations, monitoring systems, and selected diagnostic support equipment.

Industrial Control Equipment

Helps protect PLC systems, industrial PCs, monitoring devices, and control room infrastructure from power disturbances.

Financial Systems

Provides backup power for bank IT rooms, payment systems, branch infrastructure, and financial service equipment.

Security and Surveillance Systems

Supports CCTV systems, NVRs, access control systems, alarm systems, and security communication devices.

Commercial and Office IT Rooms

Suitable for business server rooms, office network systems, communication equipment, and critical IT infrastructure.

Frequently Asked Questions

What is this 6–10kVA online UPS used for?

It is designed to protect server rooms, network systems, telecom equipment, medical IT systems, industrial control devices, financial systems, and other critical loads.

What is the difference between the 1–3kVA and 6–10kVA models?

The 1–3kVA models are more suitable for smaller IT, office, and network applications. The 6–10kVA models are designed for higher loads and support features such as adjustable charging current, EPO, and extended battery configurations.

Does this UPS support adjustable charging current?

Yes. For 6kVA and 10kVA models, charging current can be adjusted via LCD or software to match different battery configurations.

Does this UPS support EPO?

Yes. Emergency Power Off function is available for 6kVA and 10kVA models, allowing fast system shutdown in emergency situations when properly connected.

Is this UPS suitable for long backup time?

Yes. Long-run models and external battery packs can be configured to support longer backup time according to load and runtime requirements.

Can this UPS work with a generator?

Yes. It is generator compatible and can work with generator input in suitable backup power environments.

Does this UPS support remote monitoring?

Yes. It supports USB and RS-232 communication, with optional SNMP for remote monitoring and power management.

Is this UPS suitable for data centers?

It can be used for small server rooms, network rooms, and critical IT systems. For medium and large data centers, a three-phase or modular UPS may be more suitable.

What information is needed to choose the right model?

To recommend the right model, provide the load capacity, input/output voltage, backup time, battery configuration, installation environment, generator status, monitoring requirements, and whether long-run operation is needed.