Features
High-Capacity Online Double-Conversion
Online double-conversion technology provides continuous power conditioning and stable output power for high-capacity critical loads.
True Galvanic Isolation Transformer
The galvanic isolation transformer helps improve electrical separation, load compatibility, and protection for sensitive or demanding equipment.
3-Phase Input / 3-Phase Output
The UPS supports 3-phase input and 3-phase output, making it suitable for large facilities and critical infrastructure requiring three-phase power protection.
High-Capacity Power Range
Available in 80kVA, 100kVA, 120kVA, 160kVA, and 200kVA, this UPS supports larger critical power applications with output power from 64kW to 160kW.
DSP Control Technology
DSP control improves system reliability, response accuracy, and operating performance for demanding power environments.
Output Power Factor 0.8
Output power factor 0.8 provides reliable active power capacity for data centers, industrial systems, telecom infrastructure, healthcare systems, and commercial facilities.
Pure Sine Wave Output
Pure sine wave output delivers clean and stable power for critical IT systems, industrial equipment, communication systems, and sensitive electronics.
Strong Overload Capability
The UPS supports temporary overload operation, helping maintain system reliability under short-term load impact conditions.
Intelligent Battery Management
Intelligent battery management helps optimize charging, protect batteries, and support longer battery service life.
Adjustable Battery Numbers
Battery numbers can be adjusted according to project requirements, backup time, and system configuration.
Dual Mains Input Support
Dual mains input support provides greater flexibility for critical power architecture and power source redundancy.
Parallel Operation up to 4 Units
Optional parallel operation with up to 4 units supports capacity expansion, redundancy, and improved system availability.
Maintenance Bypass
Maintenance bypass supports service and maintenance operations while helping maintain power continuity when properly configured.
Independent Ventilation Design
Independent ventilation improves heat dissipation and supports durable operation in continuous high-capacity applications.
Multiple Communication Options
Multiple communication options support remote monitoring, alarm integration, and power management system connection.
Optional 7-Inch Touch LCD
The optional 7-inch touch LCD provides a more intuitive interface for monitoring, operation, and system configuration.
Non-Neutral Input Support
The UPS supports applications where non-neutral input operation is required, offering more flexibility for special electrical environments.
Specifications
| MODEL | 80K | 100K | 120K | 160K | 200K | |
| PHASE | 3-phase in / 3-phase out | |||||
| CAPACITY | 80 KVA /64 KW | 100 KVA /80 KW | 120 KVA /96KW | 160 KVA /128KW | 200 KVA /160KW | |
| INPUT | ||||||
| Nominal Voltage | 3 x 380VAC/400VAC (3Ph + N) | |||||
| Acceptable Voltage Range | 285VAC ~ 475VAC | |||||
| Frequency | 50/60 Hz ± 10 % | |||||
| INVERTER | ||||||
| Nominal Voltage | 3 x 380VAC/400VAC (3Ph + N) | |||||
| Precision | Stationary: ±1%; Transitory: ±5% (load variations 100-0-100%) | |||||
| Frequency | 50/60 Hz synchronised ±1 %, With mains absent ±0.1 Hz | |||||
| Max. Synchronization Speed | ±1 Hz/s | |||||
| Waveform | Pure Sinewave | |||||
| Total Harmonic Distortion (THDv) | <2% (Linear Load) ; <5% (Non-linear Load) | |||||
| Phase Displacement | 120º ±1% (balanced load) ; 120º ±2% (imbalances 50% of the load) | |||||
| Dynamic Recovery Time | 3 cycles at 90 % of the static value | |||||
| Admissible Overload | 110% for 10min; 150% for 60sec ; >160% for 200ms | |||||
| Admissible Crest Factor | 3:1 | |||||
| Admissible Power Factor | 0.6~1 (inductive or capacitive) | |||||
| Imbalance Output Voltage @ 100% Unbalanced Load | <1% | |||||
| Current Limit | High overload, short-circuit: RMS Voltage Limit ; High Crest-Factor current: Peak Voltage Limit | |||||
| STATIC BYPASS | ||||||
| Type | Solid state | |||||
| Voltage | 3 x 380VAC/400VAC (3Ph + N) | |||||
| Frequency | 50/60 Hz | |||||
| Activation Criterion | Microprocessor control | |||||
| Transfer Time | Zero | |||||
| Admissible Overload | 150% for 1 hour; 180% for 30sec; >200% for 200ms | |||||
| Transfer to Bypass | Immediate, for overloads above 160% | |||||
| Retransfer | Automatic after alarm clear | |||||
| MAINTENANCE BYPASS | ||||||
| Type | Without interruption | |||||
| Voltage | 3 x 400V (3Ph + N) | |||||
| Frequency | 50/60 Hz | |||||
| Overall Efficiency | Line Mode | 92% | ||||
| Battery Mode | 93% | |||||
| BATTERY & CHARGER | ||||||
| Battery Type and Numbers | 12VDC x 32 pcs (29~32 pcs adjustable) | |||||
| Nominal Battery Voltage | 384 VDC (Based on 32pcs batteries) | |||||
| Charging Method | CC/CV | |||||
| Precision | ±1% | |||||
| Charging Current | Default 10A; Maximum 40A; 5A@ full load | |||||
| Charging Voltage | 432 VDC (Based on 32pcs batteries) | |||||
| PHYSICAL | ||||||
| Dimensions, D x W x H (mm) | 975 x 554 x 1286 | 1051 x 705 x 1646 | ||||
| Net Weight (Kgs) | 400 | 472 | 573 | 720 | 760 | |
| Product specifications are subject to change without further notice. | ||||||
Applications
Data Centers
Provides high-capacity 3-phase backup power for servers, storage systems, network equipment, and critical IT infrastructure.
Industrial Facilities
Suitable for automation systems, PLC platforms, production support systems, industrial servers, and factory control infrastructure.
Telecom Infrastructure
Supports communication hubs, telecom rooms, transmission systems, network infrastructure, and high-capacity telecom equipment.
Healthcare Facilities
Helps protect hospital IT rooms, laboratory systems, diagnostic support equipment, medical data platforms, and critical healthcare infrastructure.
Financial Data Centers
Provides backup power for banking data centers, payment platforms, trading support systems, transaction systems, and financial IT equipment.
Commercial Buildings
Suitable for centralized power protection in office buildings, shopping centers, public buildings, and large commercial facilities.
Emergency and Public Safety Facilities
Supports emergency operation centers, dispatch systems, command centers, public safety communication rooms, and surveillance infrastructure.
Transportation and Infrastructure Projects
Suitable for airports, rail systems, metro facilities, command centers, and other infrastructure projects requiring stable 3-phase backup power.
Frequently Asked Questions
What is this transformer 3-phase online UPS used for?
It is designed to provide high-capacity backup power and power protection for data centers, industrial facilities, telecom infrastructure, healthcare systems, financial data centers, commercial buildings, and other mission-critical 3-phase loads.
What capacity range is included in this part?
This part covers 80kVA, 100kVA, 120kVA, 160kVA, and 200kVA models.
What does 3P/3P mean?
3P/3P means 3-phase input and 3-phase output. It is suitable for facilities where both the power supply and protected loads require three-phase power.
What is the advantage of galvanic isolation?
Galvanic isolation helps provide electrical separation between input and output, improve load compatibility, and reduce the effect of certain power disturbances on sensitive equipment.
Is this UPS suitable for large data centers?
Yes. It is suitable for data centers, financial data rooms, telecom hubs, industrial facilities, and other critical environments requiring high-capacity three-phase backup power.
Does this UPS support parallel redundancy?
Yes. Optional parallel operation with up to 4 units is available for redundancy or capacity expansion.
Does this UPS support dual mains input?
Yes. Dual mains input support provides greater flexibility for critical power system design.
What is the output power factor?
The UPS provides an output power factor of 0.8, supporting reliable active power capacity for critical 3-phase loads.
What monitoring options are available?
Multiple communication options are available, and an optional 7-inch touch LCD can be used for system monitoring, operation, and configuration.
What information is needed to choose the right model?
To recommend the right configuration, the following information is usually required: load capacity, input/output voltage, required backup time, battery configuration, installation environment, redundancy requirement, communication needs, and future expansion plan.