Features
60kW Hot-Swappable Power Module
Each 60kW power module supports modular capacity expansion and easier maintenance, helping reduce service time and improve system availability.
Online Double-Conversion Technology
Online double-conversion technology provides clean, stable, and continuous power protection for sensitive and mission-critical equipment.
High Efficiency Operation
High efficiency operation helps reduce energy consumption and long-term operating costs while maintaining reliable power protection.
Unity Output Power Factor
Output power factor 1 delivers more usable active power, helping maximize UPS capacity and support modern IT, industrial, and critical power loads.
High Scalability
The modular architecture supports vertical expansion up to 10 power modules, allowing system capacity to grow according to project requirements.
N+1 or N+X Redundancy
N+1 or N+X redundancy helps improve power availability by allowing additional power modules to support critical loads if one module fails.
1+1 Cabinet Parallel Operation
The UPS supports 1+1 cabinet parallel operation, providing additional flexibility for capacity expansion or redundant system design.
Built-In Maintenance Bypass
Built-in maintenance bypass allows easier service and maintenance while helping keep critical loads powered when properly configured.
Flexible Battery Configuration
Battery configuration can be adjusted according to backup time, system voltage, and project requirements, supporting different runtime needs.
Adjustable Charging Current
Charging current is adjustable, allowing battery charging to be configured based on battery capacity and system design.
Strong Overload Capability
The UPS provides strong overload performance, supporting temporary load impact conditions and improving system robustness.
Power Walk-In Function
Power walk-in function helps reduce sudden impact on upstream power systems during startup or power recovery.
Dynamic Password Protection
Built-in dynamic password protection helps improve operation security and prevent unauthorized system settings changes.
Multiple Communication Options
Multiple communication options support convenient monitoring, system integration, and power management for critical infrastructure projects.
10-Inch Touch LCD Display
The 10-inch touch LCD display provides color dynamic power flow, operation status, module information, and charging current adjustment for easier system management.
Front-Access Maintenance Design
Front-access design helps simplify installation, inspection, module replacement, and maintenance in high-capacity power rooms.
Specifications
| MODEL | 30U-120 | 30U-180 | 42U-300 | 42U-420 | 42U-480 | 42U-600 |
| PHASE | 3-phase in / 3-phase out | |||||
| CABINET CAPACITY* | 120 KW | 180 KW | 300 KW | 420KW | 480KW | 600KW |
| BATTERY TYPE | External Battery | |||||
| ONE POWER MODULE CAPACITY | 60KVA / 60KW | |||||
| MAX. POWER MODULE NO. | 2 | 3 | 5 | 7 | 8 | 10 |
| INPUT | ||||||
| Nominal Voltage | 3 x 380/400/415 VAC (3Ph+N) | |||||
| Voltage Range | -30% ~ +20% | |||||
| Nominal Frequency | 50/60Hz (Auto Sensing) | |||||
| Frequency Range | 40Hz ~70Hz | |||||
| Power Factor | > 0.99 @ 100% Load , >0.98 @ 50% Load | |||||
| Harmonic Distortion (THDi) | < 3% @ 100% load | |||||
| OUTPUT | ||||||
| Nominal Voltage | 3 x 380/400/415 VAC (3Ph+N) | |||||
| Voltage Regulation(Steady state) | ≦± 1% Typical (balanced load) ; ≦± 2% Typical (unbalanced load) | |||||
| Nominal Frequency | 50/60Hz | |||||
| Frequency Range(Synchronized) | 46Hz ~ 54Hz or 56Hz ~ 64Hz | |||||
| Overload Capability | 1 hour for ≦ 110%, 10 mins for 111% ~ 125%, 1 min for 126%~150% and 200ms for >150% | |||||
| Harmonic Distortion | ≦2% THD (Linear Load) ; ≦4% THD (Non-linear Load) | |||||
| Efficiency | 96% | |||||
| BATTERY / CHARGER | ||||||
| Nominal Voltage | +/- 192V ~ +/- 240V (Selectable) | |||||
| Maximum Voltage | +/- 240V (12V x 40 Pcs) | |||||
| Minimum Voltage | +/- 192V (12V x 32 Pcs) | |||||
| Floating Charge Voltage | 2.28V / Cell (2.25 ~2.33 Selectable) | |||||
| Boost Charging Voltage | 2.35V/Cell | |||||
| Temperature Compensation | Yes | |||||
| Maximum Charging Current (Per Power Module) | 18A (Adjustable) | |||||
| PHYSICAL | ||||||
| Cabinet Dimension (D x W x H) mm | 1100x600x1475 | 1100x600x1475 | 1100x600x2010 | 1100x600x2010 | 1065x1000x2000 | 1065x1000x2000 |
| Net Weight (Kg) | 308 | 352 | 516 | 654 | 932 | 1020 |
| ENVIRONMENT | ||||||
| Operating Temperature | 0 ~ 40°C | |||||
| Relative Humidity | 0 ~ 95% non-condensing | |||||
| Altitude* | <1000m for Nominal power | |||||
| IP Protection | IP 20 | |||||
| MANAGEMENT | ||||||
| Smart RS-232 / USB | Supports Windows® Family, Linux and MAC | |||||
| Optional SNMP | Power management from SNMP manager and web browser | |||||
| STANDARDS | ||||||
| Safety | IEC/EN 62040-1 | |||||
| EMC | IEC/EN 62040-2 Category C3 | |||||
| ***If the UPS is installed or used in a placewhere the altitude is above than 1000m, the output power must be derated one percent per 100m. | ||||||
| Product specifications are subject to change without further notice. | ||||||
Applications
Large Data Centers
Provides scalable and redundant backup power for servers, storage systems, network equipment, and high-density IT infrastructure.
Colocation and Cloud Facilities
Suitable for critical power systems that require high capacity, redundancy, scalability, and simplified maintenance.
Telecom Facilities
Supports central offices, communication hubs, telecom rooms, transmission systems, and network infrastructure requiring stable 3-phase power.
Industrial Facilities
Helps protect industrial control rooms, PLC systems, SCADA platforms, production monitoring systems, and critical automation infrastructure.
Financial Data Centers
Suitable for banking data centers, payment platforms, trading infrastructure, transaction systems, and financial IT environments.
Healthcare Infrastructure
Supports hospital IT rooms, diagnostic centers, laboratory systems, medical data platforms, and selected critical healthcare infrastructure.
Emergency and Public Safety Facilities
Provides backup power for emergency operations centers, dispatch systems, communication rooms, surveillance systems, and mission-critical response infrastructure.
Commercial and Government Infrastructure
Suitable for large commercial buildings, public facilities, transportation hubs, command centers, and centralized power protection projects.
Frequently Asked Questions
What is this 3-phase modular online UPS used for?
This UPS is designed to provide high-capacity backup power and power protection for data centers, telecom facilities, industrial systems, financial data centers, healthcare infrastructure, and other mission-critical applications.
What capacity range does this UPS support?
This UPS supports cabinet capacities from 120kW to 600kW, depending on the cabinet configuration and the number of installed 60kW power modules.
What power module does this UPS use?
It uses a 60kW / 60kVA power module. The modular design allows modules to be added, replaced, or serviced more easily according to capacity and redundancy requirements.
What is the benefit of a 60kW modular design?
A 60kW modular design provides higher power density, easier expansion, reduced maintenance time, and flexible redundancy. It is suitable for large projects that require scalable and reliable power protection.
Does this UPS support redundancy?
Yes. It supports N+1 or N+X redundancy, helping improve system availability and reduce the risk of downtime for critical loads.
Can this UPS be expanded in the future?
Yes. The UPS supports vertical capacity expansion by adding power modules and horizontal expansion through 1+1 cabinet parallel operation, depending on the system configuration.
Does this UPS include maintenance bypass?
Yes. It includes a built-in maintenance bypass switch, which helps simplify service and maintenance while supporting continuous power to critical loads when properly configured.
What battery configuration does this UPS support?
The UPS supports flexible battery configuration, with selectable battery voltage and adjustable charging current. Backup time can be configured according to load capacity, runtime requirement, battery quantity, and project design.
What does the touch LCD display show?
The 10-inch touch LCD display provides color dynamic power flow, operation status, module information, system configuration, and charging current adjustment for easier monitoring and management.
Is this UPS suitable for large data centers?
Yes. It is suitable for large data centers, colocation facilities, cloud infrastructure, enterprise IT rooms, and other critical environments requiring high capacity, redundancy, and scalable 3-phase power protection.
What monitoring options are available?
The UPS supports communication and monitoring options such as RS-232, USB, and optional SNMP, allowing power management through monitoring software, network platforms, or web-based tools.
What information is needed to choose the right configuration?
To recommend the right UPS configuration, the following information is usually required: total load capacity, input/output voltage, phase requirement, backup time, redundancy level, battery configuration, installation environment, monitoring needs, and future expansion plan.