3P/3P Low Frequency Online UPS 160KVA to 400KVA

This low frequency 3-phase online UPS 160–400kVA provides high-capacity double-conversion power protection for large data centers, industrial facilities, telecom infrastructure, healthcare systems, financial data centers, commercial buildings, and mission-critical 3-phase loads. With pure sine wave output, 0ms transfer time, stable output voltage, 480VDC battery system, strong overload capability, and 93% efficiency, it helps protect critical equipment from outages, voltage fluctuations, surges, and power quality problems.

Designed for demanding three-phase power environments, this UPS supports 220/380/400/415/440VAC input and output configurations, maintenance-free lead-acid battery systems, bypass operation, RS232 communication, dry contact interface, EPO interface, forced-air cooling, IP21 protection, and redundancy or parallel operation. It is suitable for high-capacity applications requiring robust performance, long-term reliability, and scalable critical power protection.

Features

Low Frequency Double-Conversion Online Design

Low frequency double-conversion online design provides continuous power conditioning and stable output power for high-capacity 3-phase critical loads.

3-Phase Input / 3-Phase Output

The UPS supports 3-phase input and 3-phase output, making it suitable for large data centers, industrial facilities, commercial buildings, and critical infrastructure requiring three-phase power protection.

High-Capacity Power Range

Available in 160kVA, 200kVA, 300kVA, and 400kVA, this UPS supports large critical power applications with nominal output power from 128kW to 320kW.

Pure Sine Wave Output

Pure sine wave output provides clean and stable power for servers, telecom systems, industrial equipment, healthcare systems, financial systems, and sensitive electronic loads.

Zero Transfer Time

With online double-conversion operation, the UPS provides 0ms transfer time, helping maintain uninterrupted power during mains power disturbances.

Stable Output Voltage

Output voltage stability of ±1% under steady-state load helps ensure reliable operation for connected critical equipment.

Wide Input Voltage Support

The UPS supports 220/380/400/415/440VAC input options with wide voltage tolerance, improving adaptability in different three-phase power environments.

480VDC Battery System

The UPS uses a 480VDC battery system, supporting external maintenance-free lead-acid battery configurations for high-capacity backup power applications.

VRLA Battery Support

The UPS supports maintenance-free lead-acid battery systems, making it suitable for standard backup and long-runtime external battery configurations.

Strong Overload Capability

The UPS supports overload operation, including 110% for 300 minutes, 125% for 10 minutes, and 150% for 1 minute, helping improve reliability during temporary load impact conditions.

High System Efficiency

System efficiency up to 93% helps reduce energy loss and supports long-term operation in professional power environments.

Bypass Operation

Built-in bypass operation helps improve power continuity and supports system operation under specific overload, fault, or maintenance conditions.

Parallel and Redundancy Support

The UPS supports serial hot backup, redundancy, and parallel operation, making it suitable for projects requiring higher reliability or future capacity expansion.

Comprehensive Protection Functions

Protection functions include input protection, output protection, battery protection, temperature protection, and hardware fault protection to help improve overall system safety.

Dry Contact Interface

Dry contact interface provides alarm and status signal integration for external monitoring systems or facility management platforms.

EPO Interface

The Emergency Power Off interface allows fast shutdown in emergency situations when connected to the proper external control mechanism.

RS232 Communication

RS232 communication supports local monitoring, system communication, and basic UPS management.

LED and LCD Display

LED indicators show input, inverter, bypass, and battery status. The LCD display provides input/output voltage, frequency, load percentage, battery voltage, and internal status information.

Forced-Air Cooling

Forced-air cooling helps maintain stable thermal performance during continuous high-capacity operation.

IP21 Protection

IP21 protection provides basic protection for indoor installation environments.

Specifications

Model3C3-160KL3C3-200KL3C3-300KL3C3-400KL
Capacity160KVA200KVA300KVA400KVA
Nominal Capacity128KW160KW240KW320KW
Phase3 phase in 3 phase out
Work ModeLow frequency double conversion pure online
Power Factor>0.8
DisplayLEDIncluding the state of input, inverter, bypass and battery
LCDInput & output voltage, frequency, battery voltage, present of loads, internal humidity
RectifierInput Voltage220V/380V/400V/415V/440VAC ±30% 3 phase four wires input
Input Frequency50/60hz ± 10%
Wave FormPure sine wave
BatteryFree-maintenance, Lead-acid battery
InverterNominal Voltage220/380/400/415/440VAC
Output Voltage Stability±1% (steady-state load) ±5% (load fluctuations)
Frequency Stability50/60hz load ± 0.5%
Crest Factor>3:1
THDPure sine wave <3% (linear load)
Overload Capacity110% 300mins,125% 10mins, 150% 1mins
Efficiency93%
BypassRated VoltageFor single phase L1: 220VAC (or 230VAC), For three phase: 380VAC(or 400VAC)
Bypass Voltage Range220/380/415/440 ± 20% (10% 15% 20% adjustable)
Rated Frequency50/60hz
Bypass Frequency Range±20% (±1% to ±5% adjustable)
Transfer Time0ms
DC Voltage480VDC
ProtectionInput ProtectionOverrun high or low input, overrun frequency
Output ProtectionOvercurrent, short circuit, low power factor
Battery ProtectionOver charge, over discharge protection
Temperature ProtectionEnvironmental overheating, inverter over-temperature protection
Hardware Fault ProtectionAuxiliary power anomaly, circuit breaker tripping, fuses disconnect
and the power device over-current voltage protection
System ParameterAmbient Temperature0-40
Cooling Modeforced ventilation
Communication InterfaceRS232, dry contact interface, EPO interface
Redudancy & ParallelSerial hot backup or redundancy & parallel
Surge Capacity(0/700µs,5KV) 8/20µs, 20KVA
Protection ClassIP21
Security CapacityInput and output electrical resistance to ground 3000VAC,
leaking less than 3.5MA, insulation resistance>2Mw(500VDC)
Noise dB58dB-70dB
Dimension (mm)1420*745*18101630*1026*1900
N.W (kgs)1162121222002600
G.W (kgs)1292134224502900
* Product specifications are subject to change without further notice.

Applications

Large Data Centers

Provides high-capacity 3-phase backup power for servers, storage systems, network equipment, and critical IT infrastructure.

Industrial Facilities

Suitable for industrial control systems, automation equipment, PLC systems, monitoring platforms, production lines, and factory infrastructure.

Telecom Infrastructure

Supports telecom rooms, communication hubs, transmission systems, network infrastructure, and high-capacity communication equipment.

Healthcare Facilities

Helps protect hospital IT rooms, diagnostic support systems, laboratory equipment, medical data platforms, and selected critical healthcare infrastructure.

Financial Data Centers

Provides backup power for banking data centers, payment platforms, transaction systems, trading support infrastructure, and financial IT equipment.

Commercial Buildings

Suitable for centralized power protection in commercial buildings, office IT rooms, communication systems, security infrastructure, and building control systems.

Emergency and Public Safety Facilities

Supports emergency operation centers, dispatch systems, communication rooms, surveillance systems, and mission-critical response infrastructure.

Transportation and Infrastructure Projects

Suitable for airports, rail systems, metro facilities, command centers, and other infrastructure projects requiring stable 3-phase backup power.

Long Backup Time Projects

External VRLA battery support and 480VDC battery configuration make it suitable for applications requiring extended backup time.

Frequently Asked Questions

What is this low frequency 3-phase online UPS used for?

This UPS is designed to provide high-capacity backup power and power protection for large data centers, industrial systems, telecom infrastructure, healthcare facilities, financial data centers, commercial buildings, and other critical 3-phase loads.

What capacity range is available?

This UPS is available in 160kVA, 200kVA, 300kVA, and 400kVA models, with nominal output power from 128kW to 320kW.

What does 3P/3P mean?

3P/3P means 3-phase input and 3-phase output. It is suitable for sites where both the power supply and protected loads require three-phase power.

What is the difference between this model and the 60–120kVA version?

The 60–120kVA version is suitable for medium-to-large three-phase power applications, while this 160–400kVA version is designed for higher-capacity critical loads such as large data centers, industrial facilities, telecom infrastructure, hospitals, and commercial power systems.

What is the difference between low frequency UPS and high frequency UPS?

A low frequency UPS is generally designed for robust critical power protection and demanding electrical environments. It is often preferred for applications requiring stronger overload capability, better load adaptability, and long-term stability.

Does this UPS provide pure sine wave output?

Yes. It provides pure sine wave output, making it suitable for sensitive electronic equipment, industrial systems, telecom equipment, healthcare systems, financial systems, and critical infrastructure loads.

Does this UPS have zero transfer time?

Yes. As an online double-conversion UPS, it provides 0ms transfer time, helping protect critical loads from interruption during mains power disturbances.

What battery voltage does this UPS use?

This UPS uses a 480VDC battery system. Battery configuration should be selected according to model capacity, backup time, and project requirements.

Does this UPS support external batteries?

Yes. It supports external maintenance-free lead-acid battery systems, making it suitable for long-runtime backup power applications.

Does this UPS support parallel operation?

Yes. It supports serial hot backup, redundancy, and parallel operation, depending on project configuration and system design.

What communication interfaces are available?

The UPS supports RS232 communication, dry contact interface, and EPO interface for monitoring, alarm integration, and emergency shutdown control.

What protection functions are included?

The UPS includes input protection, output protection, battery protection, temperature protection, hardware fault protection, short-circuit protection, overload protection, and over-temperature protection.

Is this UPS suitable for industrial applications?

Yes. It is suitable for industrial control rooms, automation systems, monitoring equipment, PLC systems, production support infrastructure, and other industrial environments requiring stable high-capacity 3-phase backup power.

What information is needed to choose the right model?

To recommend the right model, the following information is usually required: load capacity, input/output voltage, backup time, battery configuration, installation environment, redundancy or parallel requirement, communication interface needs, and site power conditions.